Separation Layer Measurement in Primary Clarifier Wastewater Treatment Plant - Preclarification Application Rectangular basin 30 m x 8.5 m with two outlet funnels Basin depth 2.8 m Funnel depth 5.8 m Definition of tasks Sludge discharge control depending on the sludge level Continuous detection of b
Independent Level Measurement Independent Level Measurement Application Measuring tube with 150 mm diameter No power supply available on site Definition of tasks Groundwater level measurement at multiple level measurement spots Data logger installed in measuring tube Stable and reliable data transmi
Deep Well Level Measurement Water Supply - Groundwater Application Deep drilling 150 m Bore diameter 30 mm Definition of tasks Continuous detection of groundwater level Detection using suspended pressure probe Pressure probe appropriate for small bore diameters of 30 mm Easy installation and removal
Irrigation & Drainage Systems Flow measurement in water reservoir, in irrigation channels and to ensure minimum discharge volumes
Drinking Water Flow measurement for overnight supply, for inlets and outlets in elevated tanks as well as in water pipes. Partially contactless
Groundwater Level measurement in well shafts, for pump control and in water metering shafts. Partially with data transmission via GRPS
Special Constructions Contactless flow measurement for ensure minimum water volumes.
Power Plants Flow measurement in turbine intakes and for cooling water
Flood Protection Flow measurements for flood protection on dams or polders